Answer First
Primary Text
COMMERCIAL LAWS SUPPLEMENT
FACING — Any masonry, forming an integral part of a wall
used as a finished surface. (as contrasted to veneer, see
definition).
FIREBRICK — A refractory brick.
FIRECLAY — A finely ground clay used as a plasticizer for
masonry mortars; varies widely in physical properties.
FIREPLACE — A hearth and fire chamber or similarly
prepared place in which a fire may be made and which is
built in conjunction with a chimney.
FIRE
RETARDANT
TREATED
WOOD
—
Lumber
of
plywood impregnated with chemicals and when tested in
accordance with accepted fire standards for a period of
30 minutes shall have a flame-spread of not over 25 and
show
no
evidence
of
progressive
combustion.
The
Fire-retardant
properties
shall
not
be
considered
permanent when exposed to the weather.
FIRST STOREY — The floor of which is at or above the level
of the sidewalk or adjoining ground, the remaining
storeys being numbered in regular succession upward.
FLOOR
AREA
—
The
area
included
within
the
surrounding exterior walls of a building or portion thereof,
exclusive of vent shafts and courts. The floor area of a
building
or
portion
thereof
not
provided
with
surrounding exterior walls shall be the usable area under
the horizontal projection of the roof or floor above.
FOOTING — That portion of the foundation of a structure
which spreads and transmits loads directly to the soil or
the pile.
FOUNDATION — All the portions of the building or
structure below the footing, the earth upon which the
structure rests.
GARAGE — A building or portion thereof in which a motor
vehicle containing gasoline, distillate, or other volative,
flammable liquid in its tank, is stored, repaired, or kept.
GARAGE COMMERCIAL— A garage where automobiles
and other motor vehicle are housed, cared for, equipped,
repaired or kept for remuneration, hire, or sale.
GARAGE, OPEN PARKING — A structure of one or more
tiers in height which is at least 50 percent open on two or
more sides and is used exclusively for the parking or
storage of passenger motor vehicles having a capacity of
not more than nine persons per vehicle. Open parking
garages are further classified as either ramp-access or
mechanical-access. Ramp-access, open parking garages
are those employing a series of continuously rising floors
permitting the movement of vehicles under their own
power from and to the street level. Mechanical access
parking garages are those employing parking machines,
lifts, elevators, or other mechanical services for vehicles
moving from and to street level and in which public
occupancy is prohibited above the street level.
GARAGE PRIVATE — A building or portion of a building in
which only motor vehicles used by the tenants of the
building or buildings on the premises are stored or kept.
GIRDER — A horizontal structural piece which supports in
end of the floor beams or joists or walls over opening.
GRADE (ADJACENT GROUND ELEVATION) — The lowest
point of elevation of the finished surface of the ground
between the exterior wall of a building and a point 1.50
meters distant from said wall, or the lowest point of
elevation of the finished surface of the ground between
the exterior wall of a building and a property line if it is
less than 1.50 meters distant from sidewall. In case walls
are parallel to and within 1.50 meters of a public sidewalk,
alley, or other public way, the grade shall be the elevation
of the sidewalk, alley, or public way.
GROUND FLOOR — The storey at or near the level of the
grade, the other storeys, beginning with second for the
first next above, shall be designated by the successive
floor numbers counting upward.
GUEST ROOM — Any room or rooms used, or intended to
be used by a guest for sleeping purposes. Every 9.30
square meters of superficial floor area in a dormitory shall
be considered to be a guest room.
HABITABLE
ROOM
—
Any
room
meeting
the
requirements of this Code for sleeping, living, cooking, or
dining purposes, excluding such enclosed spaces as
closets, pantries, bath or toilet room, service rooms,
connecting corridors, laundries, unfinished attics, storage,
space cellars, utility rooms, and similar spaces.
HALL, COMMON — A corridor or passageway used in
common by all the occupants within a building.
HALL, STAIRS — A hall which includes the stair, stair
landings,
and
those
portions
of
the
common
halls
through which it is necessary to pass in going between
the entrance floor and the room.
HELIPORT — An area of land or water or a structural
surface which is used, or intended for use, the landing
and take off helicopters and any appurtenant areas which
are used, or intended for use, for heliport buildings and
other heliport facilities.
HELISTOP
—
The
same
as
heliport except that no
refueling, maintenance repairs, or storage of helicopters is
permitted.
HOTEL — A building or a part thereof with rooms
occupied
or
intended
to
be
occupied
for
hire
as
temporary aboding place of individuals with a general
kitchen and public dining room service, but no provision
for cooking in any individual suite or room.
HOTEL APARTMENT — An apartment house which may
furnish dining room service and other services for the
exclusive use of its tenants.
INCOMBUSTIBLE — As applied to building construction
material, as material which, in the form it is used, is either
one of the following:
(a) Material having an structural base of incombustible
material as defined in Item (2), above, with a surfacing
material not over 3.2 millimeters thick which has a
flame-spread rating of 50 or less.
(b) "Incombustible" does not apply to surface finish
materials.
Material
required
to be incombustible for
reduced clearance to flues, heating appliances, or other
materials
shall
refer
to
material
conforming
to
the
provisions of this Code. No material shall be classed as
incombustible
which
is
subject
to
increase
in
combustibility or flame-spread rating beyond the limits
herein established, through the effects of age, moisture,
or other atmospheric condition.
INCOMBUSTIBLE
MATERIAL
—
When
referred
to as
structural
material,
means
brick,
stone,
terracotta,
concrete, iron, steel, sheet, metal, or tiles, used either
singly or in combination.
INCOMBUSTIBLE ROOFING— A covering of not less than
two thickness of roofing felt and a good coat of tar and
gravel
or
tin,
corrugated
iron
or
other
approved
fire-resisting material with standing seam of lap joint.
INCOMBUSTIBLE
STUD
PARTITION
—
A
partition
plastered on both sides upon metal lath or wire cloth for
the full height, and fire-topped between the studs with
incombustible material 20 centimeters above the floor
and at the ceiling.
LINE, BUILDING — The line formed by the intersection of
the outer surface of the enclosing wall of the building and
the surface of the ground.
LINTEL — The beam or girder placed over an opening in a
wall, which supports the wall construction above.
LOAD, DEAD — The weight of the permanent portions of
a building or structure; it includes the weight of the walls
permanent partitions, framing floors, roofs, and all other
permanent and stationary fixtures mechanism, and other
construction entering into and becoming a part of a
building or structure.
LOAD,
LATERAL
—
That
load
cased
by
winds,
earthquakes, or other dynamic forces.
© Compiled by RGL
134 of 203
Use With Care
Definitions and exceptions often appear before or after this text.
Court decisions may interpret, limit, or apply this provision.
Confirm amendment, repeal, effectivity, and official publication.