Safety Guidelines.- Strict compliance of the following safety precautions, rules and regulations shall be observed by manufacturers, distributors and users of firecrackers and pyrotechnic devices:
a. A zone shall be designated by the local government unit where a manufacturing complex may be established. The outer perimeter of this zone shall be at least three hundred (300) meters away from the nearest residential units. Once a zone has been defined, no residential unit shall be permitted nearer than three hundred (300) meters from the perimeter of such zone;
b. The manufacturing complex shall be governed by, but not limited to, the following safety measures:
1. All buildings shall have adequate ventilation, no concrete floors, must be leak-proof and furnished with necessary fire extinguishers;
2. The warehouse must be at least fifty (50) meters away from any processing station of the complex; and
3. The following processing stations of the complex shall be laid out according to the indicated minimum distance from each other with all sides open:
(i) Mixing
-
50 MTS
(ii) Grinding
-
40 MTS
(iii) Packaging
-
40 MTS
(iv) Nagmimitsa
-
20 MTS
(v) Loading
-
20 MTS