COMMERCIAL LAWS SUPPLEMENT
structural framework, exterior walls and openings, interior
walls and enclosures, floors, exists, and stairs construction,
and roofs.
CHAPTER 5 Requirements for Fire Zones
SECTION 501. Fire Zones Defined. — Fire zones are areas
within which only certain types of buildings are permitted
to be constructed based on their use or occupancy, type
of construction, and resistance to fire.
SECTION 502. Buildings located in more than One Fire
Zone . — A building or structure which is located partly in
one fire zone and partly in another shall be considered to
be in the more highly restrictive fire zone, when more
than one-third of its total floor area is located in such
zone.
SECTION
503.
Moved
Building .
—
Any
building
or
structure moved within or into any fire zone shall be
made to comply with all the requirements for buildings in
that fire zone.
SECTION
504.
Temporary
Buildings .
—
Temporary
building
such
as
reviewing
stands
and
other
miscellaneous
structures
conforming
to
the
requirements of this Code, and sheds, canopies and
fences used for the protection of the public around and in
conjunction with construction work, may be erected in
the fire zones by special permit from the Building Official
for a limited period of time, and such buildings or
structures
shall
be-completely
removed
upon
the
expiration of the time limit stated in such permits.
SECTION 505. Center Lines of Streets . —For the purpose of
this Chapter, the center line of an adjoining street or alley
may be considered an adjacent property line. Distances
shall be measured at right angles to the street or alley.
SECTION
506.
Restrictions
on
Existing
Buildings .
—
Existing buildings or structures in fire zones that do not
comply with the requirements for a new building erected
therein
shall
not
hereafter
be
enlarged,
altered,
remodeled, repaired or moved except as follows:
(a) Such building is entirely demolished;
(b) Such building is to be moved outside the limits of the
more highly restrictive Fire Zone to a zone where the
building meets the minimum standards;
(c)
Changes,
alterations
and
repairs
may
be
made
provided that in any 12-month period, the value of the
work does not exceed twenty percent of the value of the
existing building, and provided that, such changes do not
add additional combustible material, and do not, in the
opinion of the Building Official, increase the fire hazard;
(d) Additions thereto are separated from the existing
building by fire walls, as set forth in Sub-section 604 (b);
(e) Damage from fire or earthquake, typhoons or any
fortuitous event may be repaired, using the same kind of
materials of which the building or structure was originally
constructed, Provided, That, the cost of such repair shall
not exceed twenty percent of the replacement cost of the
building or structure.
SECTION 507. Designation of Fire Zones . — The Secretary
shall promulgate specific restriction for each type of Fire
Zone. Cities and municipalities shall be divided into such
Fire Zones in accordance with local, physical, and spatial
framework plans submitted by city or municipal planning
and/or development bodies.
CHAPTER 6 Fire-Resistive Requirements in
Construction
SECTION
601.
Fire-Resistive
Rating
Defined.
—
Fire-resistive rating means the degree to which a material
can withstand fire as determined by generally recognized
and accepted testing methods.
SECTION
602.
Fire-Resistive
Time
Period
Rating .
—
Fire-resistive time period rating is the length of time a
material can withstand being burned which may be
one-hour, two-hours, three-hours, four-hours, etc.
SECTION 603. Fire-Resistive Standards . — All materials of
construction, and assemblies or combinations thereof
shall be classified according to their fire-retardant or
flame-spread ratings as determined by general accepted
testing methods and/or by the Secretary.
SECTION 604. Fire-Resistive Regulations . — The Secretary
shall
prescribe
standards and promulgate rules and
regulations on the testing of construction materials for
flame-spread characteristics, tests on fire damages, fire
tests
of
building
construction
and
materials,
door
assemblies and tinclad fire doors and window assemblies,
the installation of fire doors and windows and smoke and
fire
detectors
for
fire
protective
signaling
system,
application
and
use
of
controlled
interior
finish,
fire-resistive
protection
for
structural
members,
fire-resistive walls and partitions, fire-resistive floor or roof
ceiling,
fire-resistive
assemblies
for
protection
of
openings and fire-retardant roof coverings.
CHAPTER 7 Classification and General
Requirement of all Buildings by Use of Occupancy
SECTION
701.
Occupancy
classified.
— (a) Buildings
proposed for construction shall be identified according to
their use or the character of its occupancy and shall be
classified as follows:
(1) Group A — Residential Dwellings
Group A — Occupancies shall be dwellings.
(2) Group B — Residentials, Hotels and Apartments
—Group B Occupancies shall be multiple dwelling units
including boarding or lodging houses, hotels, apartment
buildings, row houses, convents, monasteries, and other
similar building each of which accommodates more than
ten persons.
(3) Group C — Education and Recreation — Group C
Occupancies
shall
be
buildings
used
for
school
or
day-care purposes, involving assemblage for instruction,
education, or recreation, and not classified in Group I or in
Division 1 and 2 or Group H Occupancies.
(4) Group D — Institutional — Group D Occupancies shall
include:
Division 1 — Mental hospitals, mental sanitaria, jails,
prisons,
reformatories,
and
buildings where personal
liberties of inmates are similarly restrained.
Division 2 — Nurseries for full-time care of children under
kindergarten age, hospitals, sanitaria, nursing homes with
non-ambulatory
patients,
and
similar buildings each
accommodating more than five persons.
Division 3 — Nursing homes for ambulatory patients,
homes for children of kindergarten age or over, each
accommodating more than five persons: Provided, that
Group D Occupancies shall not include buildings used
only for private or family group dwelling purposes.
(5) Group E — Business and Mercantile — Group E
Occupancies shall include:
Division 1 — Gasoline filling and service stations, storage
garages and boot storage structures where no work is
done
except
exchange
of
parts
and
maintenance
requiring no open flame, welding, or the use of highly
flammable liquids.
Division 2 — Wholesale and retail stores, office buildings,
drinking and dining establishments having an occupant
load of less than one hundred persons, printing plants,
police and fire stations, factories and workshops using
not highly flammable or combustible materials and paint
stores without bulk handlings.
Division 3 — Aircraft hangars and open parking garage
with no repair work is done except exchange of parts and
maintenance requiring no open flame, welding or the use
of highly flammable liquids.