COMMERCIAL LAWS SUPPLEMENT
(6) Group F — Industrial — Group F Occupancies shall
include: ice plants, power plants, pumping plants, cold
storage, and creameries, factories and workshops using
incombustible and non-explosive materials, and storage
and sale rooms for incombustible and non-explosive
materials.
(7) Group G — Storage and Hazardous — Group G
Occupancies shall include:
Division 1 — Storage and handling of hazardous and
highly flammable material.
Division
2
—
Storage
and
handling
of
flammable
materials, dry cleaning plants using flammable liquids;
paint stores with bulk handling, paint shops and spray
painting rooms.
Division 3 — Wood working establishments, planning
mills and box factories, shops, factories where loose
combustible fibers or dust are manufactured, processed
or
generated; warehouses where highly combustible
material is store.
Division 4 — Repair garages.
Division 5 — Aircraft repair hangers.
(8) Group H — Assembly Other Than Group I — Group H
Occupancies shall include:
Division 1 — Any assembly building with a stage and an
occupant load of less than 1000 in the building.
Division 2 — Any assembly building without stage and
having an occupant load of 300 or more in the building.
Division 3 — Any assembly building without a stage and
having an occupant load of less than 300 in the building.
Division 4 — Stadia, reviewing stands, amusement park
structures not included within Group I or in Division 1, 2,
and 3 of this Group.
(9) Group I — Assembly Occupant Load 1000 or More —
Group I Occupancies shall be any assembly building with
an age and an occupant load of 1000 or more in the
building.
(10) Group J — Accessory. — Group J Occupancies shall
include:
Division
1.
—
Private
garage,
carports,
sheds
and
agriculture buildings.
Division 2. — Fences over 1.80 meters high, tanks, and
towers.
(b) Other subgroupings or divisions within Groups A to J
may
be
determined
by
the
Secretary.
Any
other
occupancy not mentioned specifically in this Section, or
about which there is any question shall be included in the
Group which it most nearly resembles based on the
existing or proposed life and fire hazard.
SECTION 702. Change in Use . — No change shall be made
in the character of occupancy or use of any building
which would place the building in a different division of
the same group of occupancy or in a different group of
occupancies, unless such building is made to comply
with the requirements of this code for such division or
group of occupancy. The character of occupancy of
existing
buildings
may
be
changed
subject
to
the
approval of the Building Official and the building may be
occupied or purposes set forth in other Groups: Provided,
the new or proposed use is less hazardous, based on life
and fire risk, than the existing use.
SECTION
703.
Mixed
Occupancy .
—
(a)
General
Requirements. — When a building is of mixed occupancy
or used for more than one occupancy, the whole building
shall be subject to the most restrictive requirement
pertaining to any of the type of occupancy found therein
except in the following:
(1) When a one-storey building houses more than one
occupancy, each portion of the building shall conform to
the requirement of the particular occupancy housed
therein and;
(2) Where minor accessory uses do not occupy more than
ten percent of the area of any floor or a building, nor more
than ten percent of the basic area permitted in the
occupancy requirements, in which case, the major use of
the building determine the occupancy classification.
(b)
Forms
of
Occupancy
Separation
—
Occupancy
separations shall be vertical or horizontal or both, or when
necessary, of such other forms as may be required to
afford
a
complete
separation
between
the
various
occupancy divisions in the building.
(c)
Types
of
Occupancy
Separation
—
Occupancy
separation shall be classified as "One-Hour Fire-Resistive",
"Two-Hour Fire Resistive", "Three-Hour Fire-Resistive" and
"Four-Hour Fire-Resistive:
(1) A "One-Hour Fire-Resistive Occupancy Separation"
shall
be
of
not
less
than
one-hour
fire-resistive
construction. All openings in such separation shall be
protected
by
a
fire-assembly
having
a
one-hour
fire-resistive rating.
(2) A "Two-Hour Fire-Resistive Occupancy Separation"
shall
be
of
not
less
than
two-hour
fire-resistive
construction. All openings in such separation shall be
protected
by
a
fire-assembly
having
a
two-hour
fire-resistive rating.
(3) A "Three-Hour Fire-Resistive Occupancy Separation"
shall
be
of
not
less
than
three-hour
fire-resistive
construction.
All
openings
in
walls
forming
such
separation shall be protected by a fire assembly having a
three-hour fire-resistive rating. The total width of all
openings
in
any
three-hour
fire-resistive
occupancy
separation wall in any one-storey shall not exceed 25 per
cent of the length of the wall in that storey and no single
opening shall have an area greater than 10.00 square
meters. All openings in floors forming a "Three-Hour
Fire-Resistive Occupancy Separation" shall be protected
by vertical enclosures extending above and below such
openings. The walls of such vertical enclosures shall be of
not less than two-hour fire-resistive construction, and all
openings therein shall be protected by a fire-assembly
having a three-hour fire-resistive rating.
(4) A "Four-Hour Fire-Resistive Occupancy Separation"
shall have no openings therein and shall be of not less
than four-hour fire resistive construction.
(d) Fire-Rating for Occupancy Separation — Occupancy
Separations
shall
be
provided
between
groups,
subgroupings, or divisions of occupancies. The Secretary
shall promulgate rules and regulations for appropriate
occupancy separations in buildings of mixed occupancy:
Provided,
that,
where
any
occupancy
separation
is
required,
the
minimum
shall
be
a
"One-Hour
Fire-Resistive Occupancy Separation"; and where the
occupancy separation is horizontal, structural member
supporting
the separation shall be protected by an
equivalent fire-resistive construction.
SECTION 704. Location of Property . — (a) General — No
Building shall be constructed unless it adjoins or has
direct access to a public space yard or street on at least
one of its sides.
For the purpose of this Section, the center line of an
adjoining street or alley shall be considered an adjacent
property line.
Eaves over required windows shall not be less than 750
millimeters from the side and rear property lines.
(b) Fire Resistance of Walls .— Exterior walls shall have fire
resistance and opening protection in accordance with the
requirements
set
forth by the Secretary. Projections
beyond the exterior wall shall not exceed beyond a point
one-third the distance from an assumed vertical plane
located where the fire-resistive protection of openings is
first required to the location on property whichever is the
least restrictive. Distance shall be measured at right
angles from the property line. When openings in exterior
walls are required to be protected due to distance from
property line, the sum of the areas of such openings in