COMMERCIAL LAWS SUPPLEMENT
(b) The walkway shall be capable of supporting a uniform
live load of 650 kilograms per square meter. A durable
wearing
surface
shall
be
provided
throughout
the
construction period.
SECTION 1106. Pedestrian Protection . — (a) Protection
Required . — Pedestrian traffic shall be protected by a
railing on the street side when the walkway extends into
the roadway, by a railing when adjacent to excavations,
and by such as set forth in Table 1106-A: Type of Projection
Required for Pedestrians (Annex B-2)
(b) Railings . — Adequate railings when required shall be
built substantially strong and should be at least 1.00
meter in height.
(c) Fences . — Fences shall be built of an approved
material, not less than 2.40 meters in height above grade,
and be placed on the side of the walkway nearest to the
building site. Fences shall enclose entirely the building
site. Openings in such fences shall be provided with doors
which shall be keep closed at all times.
(d) Canopies . — The protective canopy shall have a clear
height of 2.40 meters above the railway, and shall be
structurally safe. Every canopy shall have a solid fence
built along its entire length on the construction side. If
materials are stored or work is done on top of the canopy,
the edge along the street shall be protected by a tight
curb board not less than 300 millimeters high and an
railing not less than 1.00 meter high shall be provided.
The entire structure shall be designed to carry the loads
imposed upon it: Provided, that the live load shall be not
less than 600 kilograms per square meter.
SECTION 1107. Maintenance and Removal of Protective
Devices . — (a) Maintenance . — All protective devices shall
be properly maintained in place and kept in good order
for
the
entire
length
of
time
pedestrians
may
be
endangered.
(b) Removal . — Every protective fence or canopy shall be
removed within 30 days after such protection is no longer
required as determined by the Building Official.
SECTION 1108. Demolition . — (a) The work of demolishing
any building shall not be commended until all the
necessary pedestrian protective structures are in place.
(b) The Building Official may require the permittee to
submit plans, specifications and complete schedule of
demolition. When so required, no work shall be done until
such plans, specifications and schedule are approved by
the Building Official.
CHAPTER 12 General Design and Construction
Requirements
SECTION
1201.
General
Requirement .
—
Buildings
proposed
for construction shall comply with all the
regulations and specifications herein set forth governing
quality,
characteristics
and
properties
of
materials,
methods of design and construction, type of occupancy
and classification.
All other matters relative to the structural design of all
buildings and other structures not provided for in this
Chapter shall conform with the provisions of the National
Structural
Code
of
Buildings,
as
adopted
and
promulgated by the Board of Civil Engineering pursuant
to the Republic Act Number 544, as amended, other wise
known as the "Civil Engineering Law".
SECTION 1202
Excavation, Foundation and Retaining
Wall . — (a) Subject to the provisions of Articles 684 to 686
of
the
Civil Code of the Philippines on lateral and
subjacent support, the design and quality of materials
used
structurally
in
excavation,
footings,
and
in
foundations
shall
conform
to
accepted
engineering
practice.
(b) Excavation and Fills — (1) Excavation or fills for
buildings
or
structures
shall
be
so
constructed
or
protected that they do not endanger life or property.
(2)
Whenever
the
depth
of
excavation
for
any
construction
is
such
that
the lateral and subjacent
support of the adjoining property or existing structure
thereon would be affected in a manner that the stability
or
safety
of
the
same
is
endangered,
the
person
undertaking or causing the excavation to be undertaken
shall be responsible for the expense of underpinning or
extending
the
foundation
or
footings
of
the
aforementioned property or structure.
(3) Excavation and other similar disturbances made on
public property shall, unless otherwise excluded by the
Building Official, be restored immediately to its former
condition
within
48
hours
from
the
start
of
such
excavation and disturbances by whosoever caused such
excavation or disturbance.
(c) Footings, Foundations, and Retaining Walls — (1)
Footings and foundations shall be of the appropriate
type, of adequate size, and capacity in order to safely
sustain the superimposed loads under seismic or any
conditions of external forces that may affect the safety or
stability of the structure. It shall be the responsibility of
the architect and/or engineer to adopt the type and
design of the same in accordance with the standards set
forth by the Secretary.
(2) Whenever or wherever there exists in the site of the
construction an abrupt change in the ground levels or
level of the foundation such that instability of the soil
could result, retaining walls shall be provided and such
shall be of adequate design and type of construction as
prescribed by the Secretary.
SECTION 1203. Veneer . — (a) Definition . — Veneer is a
non-structural facing of brick, concrete, tile, metal, plastic,
glass, or other similar approved materials attached to a
backing or structural components of the building for the
purpose of ornamentation, protection, or enclosure that
may be adhered, integrated, or anchored either on the
interior or exterior of the building or structure.
(b) Design Requirements . — The design of all veneer shall
comply with the following:
(1) Veneer shall support no load other than its own weight
and the vertical dead load of veneer immediately above.
(2) Surfaces to which veneer is attached shall be designed
to
support
the
additional
vertical
and
lateral
loads
imposed by the veneer.
(3) Consideration shall be given to differential movements
of the supports including those caused by temperature
changes, shrinkage, creep, and deflection.
(4) Adhered veneer and its backing shall be designed to
have
a
bond
to the supporting elements sufficient
seismic effects on the total assemblage.
(5) Anchored veneer and its attachment shall be designed
to resist horizontal forces equal to twice the weight of the
veneer.
(6) Anchors supports and ties shall be non-combustible
and corrosion-resistant.
SECTION 1204. Enclosure of Vertical Openings . — (a)
General .
—
Vertical
openings
shall
be
enclosed
depending upon the fire-resistive requirements of a
particular type of construction as set forth in this Code.
(b) Elevator Enclosures . — Walls and partitions enclosing
elevators and escalators shall be of not less than the
fire-resistive construction required under the Types of
Construction. Enclosing Walls of elevator shafts may
consist of wire glass set in metal frames on the entrance
side only. Elevator shafts extending through more than
two storeys shall be equipped with an approved means of
adequate ventilation to and through the main roof of the
building:
Provided ,
that
in
those
buildings
housing
Groups F and G Occupancies equipped with automatic
fire-extinguishing systems throughout, enclosures shall
not be required for escalators: Provided , further, that the
top of the escalator opening at each storey shall be
provided with a draft curtain. Such draft curtain shall
enclose the perimeter of the unenclosed opening and