CHAPTER 17 Sheet Metal Paint Spray Booths
SECTION 1701. Sheet Metal Paint Spray Booths . — (a)
General — Paint spray booths shall be constructed of
steel of not less than No. 18 U.S. gauge in thickness and
shall be designed in accordance with this Code.
(b) Area — The area of a paint spray booth shall not
exceed 150 square meters not ten percent of the basic
area permitted for the major of the building according to
its Occupancy Group.
(c) Floor Construction — The floor shall be constructed of
incombustible material.
(d)
Interior
Surface .—
Paint
spray
booths
shall
be
designed to permit the free passage of the exhaust air
from all parts of the interior and all interior surface shall
be smooth and continuous without outstanding edges.
SECTION 1702. Fire Protection . — Every spray booth
having an open front elevation larger than 1.00 square
meter and which is not equipped with doors, shall have a
fire
curtain
or
metal
deflector
not
less
than
100
millimeters deep installed at the upper outer edge of the
booth opening.
SECTION 1703. Light . — Paint spray booths shall be
illuminated
through
hammered wire or heat-treated
glass panels. The glass panels shall be located in such a
manner as to reduce the hazard of ignition caused by
paint spray deposit.
SECTION 1704. Ventilation . — (a) General — Mechanical
ventilation shall be provided direct to the exterior of the
building.
The
mechanical
exhaust
system
shall
be
designed to move the air through any portion of the paint
spray area at the rate of not less than 30.00 lineal meters
per
minute.
The
blades
of
exhaust
fans
shall
be
constructed
of
non-ferrous
material
and
shall
be
mounted in such a manner as to prevent contact with the
exhaust duct. The motor shall not be mounted in the
spray booth or the duct system and belts shall be
enclosed where they enter the booth or duct system.
(b) Exhaust Ducts . — Exhaust ducts shall be constructed
of steel having a thickness not less than the values set by
the Secretary. The discharge point for ducts in a paint
spray booth shall be not less than 2.00 meters from the
adjoining combustible construction nor less than 8.00
meters from adjoining exterior wall openings: Except ,
that
the
discharge
point
for
exhaust
ducts
is
not
regulated in a waterwash spray booth.
CHAPTER 18 Glass and Glazing
SECTION 1801. General Requirements —(a) This Chapter
shall apply to exterior glass and glazing in all Occupancies
except Groups A, B, and J Occupancies not over three
storeys in height, and to interior and exterior glass and
glazing in all occupancies subject to human impact as
specified in this Code.
(b) Standards for materials shall conform to the provisions
set by the Secretary on glass dimensional tolerances,
breaking stress levels, and design safety factors.
(c)
Each
light
shall
bear
the
manufacturer's
label
designating the type and thickness of glass. Each light
with
special
performance
characteristics
such
as
laminated,
heat
strengthened
fully
tempered
or
insulated, shall bear the manufacturer's identification
showing the special characteristics and thickness by
etching or other permanent identification that shall be
visible after the glass is glazed.
SECTION 1802. Area Limitation . — Exterior glass and
glazing shall be capable of safely withstanding the load
due to wind pressures for various height zones above
ground acting inward or outward. The area of individual
lights shall not be more than the maximum allowable
area of glass according to the wind load multiplied by the
appropriate adjustment factor.
SECTION 1803. Glazing . — Glass firmly supported on all
four edges shall be glazed with minimum laps and edge
clearances in accordance with Section 1801 paragraph (b),
Provided, that glass edge clearance in fixed openings
shall be not less than what is required for wind and
earthquake drift. For glass not firmly supported on all four
edges and design shall be submitted for approval of the
Building Official. Glass supports shall be considered firm
when deflection of the support at design load does not
exceed 1/175 of the span.
SECTION
1804. Louvered Windows . — Regular plate,
sheet,
or
patterned
glass
in
jalousies
and louvered
windows
shall
not
be
thinner
than
5.6
millimeters
minimal and not longer than 1.20 meters. Exposed glass
edges shall be smooth.
SECTION 1805. Impact . — Frameless glass doors, glass in
doors, fixed glass panels, and similar glazed openings
which may be subject to accidental human impact shall
conform with the requirements set forth by the Secretary
on impact loads of glass: Except in the following cases:
(1) Bathtub and shower enclosures shall be constructed
from approved shatter-resistant materials, such as: wire
reinforced glass not less than 5.6 millimeters thick; fully
tempered glass not less than 4.8 millimeters thick: or
laminated safety glass not less than 6.4 millimeters thick.
(2) Glass lights located not less than 450 millimeters
above the adjacent finished floor or walking surface.
(3) Glass lights when the least dimension is not greater
than 450 millimeters.
(4) Glass lights 1.50 square meters or less in area.
CHAPTER 19 The Use of Computers
SECTION 1901. General Rule . — The use of computers for
all or any part of the design of buildings under this Code
is permitted provided that all programs to be used are
documented.
SECTION
1902.
Program
Documentation .
—
Documenting a program under this Code consists of
filing
with
the
Building
Official
a
reference
to
a
publication or publications accessible to him were the
detailed description of the program or a brief statement
of the theoretical background of the program including a
description of the algorithms used are found.
SECTION
1903.
Submission
of
Computer-Generated
Computations .
—
A
copy
of
the
output
sheets for
computer-generated computations shall be submitted as
a part of the design computations. The out sheets shall
be accompanied by a certification of a designer and/or
consultant
that
the
output
sheets
are
the
results
obtained through the use of documented programs. The
certification
should include the identification of the
specific
program
used
for
each
portion
of
the
computer-generated computations being submitted.
CHAPTER 20 Signs
SECTION 2001. General Requirements . — (a) No sign or
signboard shall be erected in such manner as to confuse
or obstruct the view or interpretation of any official traffic
sign, signal, or device.
(b)
No sign or signboard shall be constructed as to
unduly
obstruct
the
natural view of the landscape,
distract or obstruct the view of the public as to constitute
a traffic hazard, or otherwise defile, debase or offend
aesthetic and cultural values and traditions.
SECTION 2002. Maintenance . — All signs, together with
all of their supports, braces, guys and anchors, shall be
kept in repair and in proper state of preservation. The
© Compiled by RGL
131 of 203
Use With Care
Definitions and exceptions often appear before or after this text.
Court decisions may interpret, limit, or apply this provision.
Confirm amendment, repeal, effectivity, and official publication.