CHAPTER 16 Plastics
SECTION 1601. Approved Plastics . — Approved plastic
materials shall be those which have a flame-spread rating
of 225 or less and a smoke density not greater than that
obtained from the burning of untreated wood under
similar
conditions
when
tested
in
accordance
with
generally accepted engineering practices. The products
of combustion shall be no more toxic than the burning of
untreated wood under similar conditions.
SECTION 1602. Installation . — (a) Structural Requirements
— All plastic materials shall be of adequate strength and
durability
to
withstand
the prescribed design loads.
Sufficient
and
substantial
technical
data
shall
be
submitted to establish stresses, maximum unsupported
spans, and such other information as may be deemed
necessary for the various thicknesses and forms used.
(b)
Fastenings
—
Fastenings
shall
be
adequate
to
withstand design loads and internal and external stresses
required of the assembly. Proper allowances of plastic
materials in conjunction with other materials with which
it is assembled or integrated shall be provided.
SECTION 1603. Glazing of Openings . — (a) Doors, sashes
and framed openings in exterior walls of all buildings
except Types IV and V Constructions may be glazed or
equipped with approved plastics: Provided, that:
(1) The wall in which such glazing is installed is so located
that openings are not required to be fire-protected.
(2) Except for Type I Construction, the location size, and
spacing of such glazed openings do not exceed the
values set forth by the Secretary.
(3)
Plastic
used
in
glazed
openings
for
Type
II
Construction
shall
be
materials
appropriate
for
use
according
to
flame-spread
characteristics
and
the
location, size, and spacing of the openings do not exceed
the values set forth by the Secretary.
SECTION 1604. Skylights . — (a) General — Approved
plastics may be used in skylights installed on roofs of
Types I, II, or III constructions and all buildings in these
categories shall be equipped with an approved automatic
fire-extinguishing system in Groups A, B, C, E, F, J, H-3 and
H-4 Occupancies: Except , that:
(1)
Approved
plastics
may
be
used
in
any type of
construction or occupancy as a fire venting system when
approved by the Building Official.
(2) Plastic may be used in approved skylights in Type II
one-hour fire-resistive construction which are located 300
millimeters or more above the lower place of the ceiling.
The walls of the skylight well shall be no less fire-resistive
than the adjacent ceiling.
(3)
Where
fire-resistive
ceiling
is
not
required
in
one-storey buildings, approved plastics may be used in
skylights.
(b) Installation Requirements . — (1) Except in Group A
Occupancies, no skylight shall be installed within 3.00
meters of a property line.
(2) The edges of dome-type skylights shall be properly
flashed.
(3) Plastic skylights shall be separated from each other by
at least 2.50 meters laterally and 3.00 meters along the
slope of the roof.
(c) Allowable Areas — The area of individual plastic
skylights shall not exceed 10.00 square meters. The total
aggregate area of plastics used in skylights, monitors, and
sawtooth glazing shall not exceed twenty percent of the
floor area of the room or occupancy sheltered.
(d) Curb Requirements — Plastic skylights in roofs having
a slope of less than 1 in 3 shall have a 100 millimeters high
curb. The curb may be omitted where a wire screen not
smaller than No. 12 U.S. gauge with a mesh not larger
than 25 millimeters is provided immediately below the
skylight. The screen shall be substantially mounted below
the skylight.
SECTION 1605. Light-Transmitting Panels in Monitors and
Sawtooth Roofs . — (a) General — Where a fire-resistive
rating is not required for the roof structure, and in all
buildings
provided
with
an
approved
automatic
fire-extinguishing system, approved plastics may be used
with or without such as the light-transmitting medium in
monitors and sawtooth: Except , that plastics used in
monitors or sawtooth roofs of Type II Construction shall
be of materials appropriate to be used according to
flame-spread characteristics.
(b) Allowable Area — The area of individual plastic glazing
used in monitors and sawtooth glazing shall not exceed
15.00 square meters. The total aggregate area of plastics
used in skylights, monitors, and sawtooth glazing shall
not exceed twenty percent of the floor area of the room or
occupancy sheltered.
(c) Area Separation — The area of such plastic panels
shall be separated from each other by a section of
incombustible material or by a section of the roofing
material of the structure not less than 1.50 meters in
length. The lower edge of the plastic material shall be at
least 150 millimeters above the surface of the adjoining
roof surface.
SECTION 1606. Plastic Light Diffusers in Ceilings . — (a)
General — Ceiling light diffusers having an area greater
than ten percent of any 10.00 square meters of room area
shall
be
of
approved
plastics
conforming
to
the
requirements specified in this Code.
(b) Installation — Plastic light diffusers shall be installed in
such
a
manner
that
they
will
not
readily
become
detached when subjected to room temperature of 80ºC
for 15 minutes, Except , for the plastic light diffusers which
are installed in the first floor area of Group C Occupancies
having egress directly to the exterior of the building; and
plastic light diffusers which are located between an
approved automatic fire-extinguishing system and the
area to be protected other than public corridors for Group
A, B, C, D, E, G, H and I Occupancies if tests required by
the Secretary have established that such installation will
not
interfere
with
the
efficient
operation
of
such
automatic fire-extinguishing systems.
SECTION 1607. Partitions . — Where partitions are not
required
to
be
of
fire-resistive
or
incombustible
construction,
approved
plastics
conforming
to
the
requirements specified in this Code may be used.
SECTION 1608. Exterior Veneer . — (a) General — Exterior
veneer may be of approved plastic materials, and shall
conform to the provisions of this Section.
(b) Height — Plastic veneer shall not be attached to any
exterior wall above the first storey: Provided, that plastic
veneer may be attached to exterior walls above the first
storey of buildings located outside of highly restrictive
Fire Zones: Provided, further that the height of the veneer
is not in excess of 10.00 meters above the adjacent of
elevation.
(c) Area — Sections of plastic veneer shall not exceed
15.00 square meters in area, Except, that in less restrictive
Fire Zones, the area may be increased by fifty percent.
(d) Separation — Sections of plastic veneer shall be
separated by a minimum of 1.20 meters vertically and 600
millimeters horizontally.
SECTION 1609. Awnings and Canopies . — (a) Plastic
materials appropriate for use according to Flame Spread
characteristics may be utilized in awnings and canopies,
provided such awnings and canopies are constructed in
accordance with provisions governing projections and
appendages as specified in this Code.