COMMERCIAL LAWS SUPPLEMENT
from any storey of a building shall be determined by
using
the
occupant
load
of
that
storey
plus
the
percentage of the occupant loads of floors which exits
through the level under consideration as follows: fifty (50)
per cent of the occupant load in the first adjacent storey
above (and the first adjacent storey below when a storey
below exits through the level under consideration) and
twenty five per cent of the occupant load in the storey
immediately
beyond
the
first
adjacent
storey.
The
maximum exit width from any storey of a building shall
be maintained.
(3) Arrangement of Exits . — If only two exits are required
they shall be placed a distance apart to not less than
one-fifth of the perimeter of the area served measured in
a straight line between exits. Where three or more exits
are required they shall be arranged a reasonable distance
apart so that if one becomes blocked, the others will be
available.
(4) Distance to Exits . — No point in a building without a
sprinkle system shall be more than 45.00 meters from an
exterior exit door, a horizontal exit, exit passageway, or an
enclosed stairway, measured along the line of travel. In a
building
equipped
with
a
complete
automatic
fire
extinguishing system the distance from exits may be
increased to 60.00 meters.
(c) Doors . — The provisions herein shall apply to every exit
door serving an area having an occupant load of more
than 10 or serving hazardous rooms or areas.
(1) Swing . — Exit door shall swing in the direction of exit
travel when serving any hazardous areas or when serving
an occupant load of 50 or more. Double acting doors shall
not be used as exits serving a tributary occupant load of
more than 100; nor shall they be used as a part of fire
assembly, nor equipped with public hardware. A double
acting door shall be provided with a view panel of not less
than 1,300 square centimeters.
(2) Type of Lock or Latch . — Exit door shall be openable
from the inside without the use of a key or any special
knowledge or effort: Except , that this requirement shall
not apply to exterior exit doors in a Group E or F
Occupancy if there is a conspicuous, readily visible and
durable sign on or adjacent to the door, stating that the
door is to remain unlocked during business hours. The
locking device must be of a type that will readily be
distinguishable as locked. Flush bolts or surface bolts are
prohibited.
(3) Width and Height . — Every required exit doorway shall
be of a size as to permit the installation of a door not less
than 900 millimeters in width and not less than 2.00
meters in height. When installation in exit doorways, exit
doors shall be capable of openings at least 90 decrees
and shall be so mounted that the clear width of the exit
way is not less than 700 millimeters. In computing the
required exit width the net dimension of the exitway shall
be used.
(4) Door Leaf Width . — No leaf of an exit door shall exceed
1.20 meters in width.
(5) Special Doors . — Revolving, sliding, and overhead
doors shall not be used as required exits.
(6) Egress from Door . — Every required exit door shall give
immediate access to an approved means of egress from
the building.
(7) Change in Floor Level at Doors . — Regardless of the
occupant load there shall be a floor or landing on each
side of an exit door. The floor or landing shall be leveled
with, or not more than 50 millimeters lower than the
threshold of the doorway: Except , that in Group A and B
occupancies, a door may open on the top step of a flight
of stairs or an exterior landing provided the door does not
swing over the top step or exterior landing and the
landing is not more than 200 millimeters below the floor
level.
(8) Door Identification . — Glass doors shall conform to the
requirements in Section 1005. Other exit doors shall be so
marked that they are already distinguishable from the
adjacent construction.
(9)
Additional
Doors .
—
When
additional doors are
provided for egress purposes, they shall conform to all
provisions in the following cases: Approved revolving
doors having leaves which will collapse under opposing
pressures may be used in exit situations: Provided, That
such doors have a minimum width of 2.00 meters or they
are not used in occupancies where exits are required to
be
equipped
with
panic
hardware
or
at
least
one
conforming exit door is located adjacent to each revolving
doors installed in a building and the revolving door shall
not be considered to provide any exit width.
(d) Corridors and Exterior Exit Balconies . — The provisions
herein shall apply to every corridor and exterior exit
balcony serving as required exit for an occupant load of
more than ten.
(1) Width . — Every corridor or exit balcony shall not be less
than 1.10 meters in width.
(2) Projections . — The required width of corridors and
exterior exit balconies shall be an obstructed: Except that
trim handrails, and doors when fully opened shall not
reduce the required width by more than 200 millimeters.
Doors in any position shall not reduce the required width
of the corridor by more than one-half.
(3) Access to Exits . — When more than one exit is
required, they shall be arranged to allow going to either
direction from any point dead ends permitted by this
Code.
(4) Dead Ends . — Corridors and exterior exit balconies
with dead ends are permitted when the dead end does
not exceed 6.00 meters in length.
(5) Construction . — Walls and ceilings of corridors shall
not be less than one-hour fire-resistive construction.
Provided , that this requirement shall not apply to exterior
exit
balconies,
railings,
and
corridors
of
one-storey
building housing a Group E and F Occupancy occupied
by one tenant only and which serves an occupant load of
30
or
less,
nor
to
corridors,
formed
by
temporary
partitions. Exterior exit balconies cannot project into an
area where protected openings are required.
(6) Openings . — Where corridor wall are required to be
one-hour fire-resistive construction, every interior door
opening shall be protected as set forth in generally
recognized and accepted requirements for dual purpose
fire exit doors. Other interior openings except ventilation
louvers equipped with approved automatic fire shutter
shall be 7 millimeters thick fixed wire glass set in steel
frames. The total area of all openings other than doors, in
any portion of an interior corridor wall shall not exceed
twenty-five percent of the area of the corridor wall of the
room being separated from the corridor.
(e) Stairways . — Except stairs or ladders used only to
access, equipment, every stairway serving any building or
portion
thereof
shall
conform
to
the
following
requirements:
(1) Width . — Stairways serving an occupant load of more
than 50 shall not be less than 1.10 meters. Stairways
serving an occupant load of 50 or less may be 900
millimeters wide. Private stairways serving an occupant
load of less than 10 may be 750 millimeters. Trim and
handrails shall not reduce the required width by more
than 100 millimeters.
(2) Rise and Run . — The rise of every step in a stairway
shall not exceed 200 millimeters and the run shall not less
than 250 millimeters. The maximum variations in the
height of risers and the width of treads in any one flight
shall be 5 millimeters: Except , in case of private stairways
serving an occupant load of less than 10, the rise may be
200 millimeters and the run may be 250 millimeters,
except as provided in sub-paragraph (3) below.
(3) Winding Stairways . — In Group A Occupancy and in
private stairways in Group B Occupancies, winders may
be used if the required width of run is provided at a point
not more than 300 millimeters from the side of the
© Compiled by RGL
121 of 203