stairway where the treads are narrower but in no case
shall any width of run be less than 150 millimeters at any
point.
(4) Circular Stairways . — Circular stairs may be used as an
exit provided the minimum width of run is not less than
250 millimeters. All treads in any one flight between
landings
shall have identical dimensions within a 5
millimeter tolerance.
(5) Landings . — Every landing shall have a dimension
measured in the direction of travel equal to the width of
the
stairway. Such dimension need not exceed 1.20
meters when the stairs has a straight run. Landings when
provided shall not be reduced in width by more than 100
millimeters by a door when fully open.
(6)
Basement Stairways . — Where a basement stairway
and a stairway to an upper storey terminate in the same
exit enclosure, an approved barrier shall be provided to
prevent persons from continuing on to the basements.
Directional exit signs shall be provided as specified in this
Code.
(7) Distance Between Landings . — There shall be not
more
than
3.60
meters
vertical
distance
between
landings.
(8) Handrails . — Stairways shall have handrails on each
side and every stairway required to be more than 3.00
meters in width shall be provided with not less than one
intermediate handrail for each 3.00 meters of required
width.
Intermediate
handrail
shall
be
spaced
approximately
equal
within
the entire width of the
stairway. Handrails shall be placed not less than 800
millimeters nor more than 900 millimeters above the
nosing of treads and ends of handrails shall be returned
or shall terminate in nowel posts or safety terminals:
Except , in the following cases: Stairways 1.10 meters or less
in width and stairway serving one individual dwelling unit
in Group A or B Occupancies may have one handrail,
except that such stairway open on one or both sides shall
have handrails provided on the open side or sides: or
stairway having less than four risers need not have
handrails.
(9) Exterior Stairway Protection . — All openings in the
exterior wall below or within 3.00 meters, measured
horizontally of an exterior exit stairway serving a building
over two storeys in height shall be protected by a
self-closing fire assembly having a three-fourths hour
fire-resistive
rating:
Except, that
opening
may
be
unprotected when two separated exterior stairways serve
an exterior exit balcony.
(10) S tairway Construction-Exterior . — Exterior stairway
shall be of incombustible material: Except, that on Type III
buildings which do not exceed two storeys in height,
which are located in less fire-restrictive Fire Zones, as well
as on Type I buildings may be of wood not less than 50
millimeters in nominal thickness. Exterior stairs shall be
protected as required for exterior walls due to location on
property as specified in this Code. Exterior stairways shall
not project into an area where openings are required to
be protected. Where there is enclosed usable space
under stairs, the walls and soffits of the enclosed space
shall be protected on the enclosed side as required for
one-hour fire-resistive construction.
(11) Stairway to Roof . — In every building four or more
storeys in height, one stairway shall extend to the roof
unless the roof has C slope greater than 1 in 3.
(12) Headroom . — Every required stairway shall have a
headroom clearance of not less than 2.00 meters. Such
clearance shall be established by measuring vertically
from a plane parallel and tangent to the stairway tread
nosing to the soffit above all points.
(f) Ramps . — A ramp conforming to the provisions of this
Code may be used as an exit. The width of ramps shall be
as required for corridors.
(g) Horizontal Exit . — If conforming to the provisions of
this Code, a horizontal exit may be considered as the
required exit. All openings in a separation wall shall be
protected by a fire assembly having a fire-resistive rating
not less than the occupant load served by such exit. The
capacity shall be determined by allowing 0.30 square
meter of net floor area per ambulatory occupant and 1.90
square
meters
per
non-ambulatory
occupant.
The
dispersal area into which the horizontal exit loads shall be
provided with exits as required by this Code.
(h)
Exit Enclosures . — Every interior stairway, ramp, or
escalator shall be enclosed as specified in this Code:
Except, that in other than Group D Occupancies, as an
enclosure will not be required for stairway, ramp, or
escalator
serving
only
one
adjacent
floor
and
not
connected with corridors or stairways serving other floors.
Stairs in Group A Occupancies need not be enclosed.
(1)
Enclosure
walls
shall not be less than two-hour
fire-resistive construction. There shall be no openings into
exit enclosures except exit doorways and openings in
exterior walls. All exit doors in an exit enclosure shall be
appropriately protected.
(2) Stairway and ramp enclosures shall include landings
and parts of floors connecting stairway flights and shall
include a corridor on the ground floor leading from the
stairway to the exterior of the building. Enclosed corridors
of
passageways
are
not
required
from
unenclosed
stairways.
(3) A stairway in an exit enclosure shall not continue
below the grade level exit unless an approved barrier is
provided at the ground floor level to prevent persons
from accidentally continuing into the basement.
(4)
There shall be no enclosed usable space under
stairways in an exit enclosure, nor shall the open space
under such stairways be used for any purpose.
(i) Smokeproof Enclosures — A smokeproof enclosure
shall consist of a vestibule and a continuous stairway
enclosed from the highest point to the lowest point by
walls of two-hour fire-resistive construction. In building
five storeys or more height, one of the required exits shall
be a smokeproof enclosure.
(1)
Stairs
in
smokeproof
enclosures
shall
be
of
incombustible construction.
(2) There shall be no openings in smokeproof enclosures,
except exit doorways and openings in exterior walls. There
shall be no openings directly into the interior of the
building. Access shall be through a vestibule with one
wall at least fifty percent open to the exterior and having
an exit door from the interior of the building and exit
door leading to the smokeproof enclosure. In lieu of a
vestibule, access may be by way of an open exterior
balcony of incombustible materials.
(3) The opening from the building to the vestibule or
balcony
shall
be
protected
with
a
self-closing
fire
assembly
having
one-hour
fire-resistive
rating.
The
opening from the vestibule or balcony to the stair tower
shall be protected by a self-closing fire assembly having a
one-hour fire-resistive rating.
(4) A smokeproof enclosure shall exit into a public way or
into an exit passageway leading to a public way. The exit
passageway shall be without other openings and shall
have walls, floors, and ceilings of two-hour fire-resistance.
(5)
A
stairway
in
a smokeproof enclosure shall not
continue below the grade level exit unless an approved
barrier is provided at a ground floor level to prevent
persons from accidentally walking into the basement.
(j) Exit Outlets, Courts, and Passageways — Every exit
shall discharge into a public way, exit court, or exit
passageway. Every exit court shall discharge into a public
way or an exit passageway. Passageways shall be without
openings other than required exits and shall have walls,
floors, and ceilings of the same period of fire-resistance as
the walls, floors and ceilings of the building but shall not
be less than one-hour fire-resistive construction.
(1) Width — Every exit court and exit passageway shall be
at least as wide as the required total width of the tributary
exits, such required width being based on the occupant