COMMERCIAL LAWS SUPPLEMENT
when the guardrail is parallel and adjacent to the aisle:
Except,
that
the
height
may
be
reduced
to
900
millimeters
for
guardrails
located
in
front
of
the
grandstand.
(6.3) A midrail shall be placed adjacent to any seat to limit
the open distance above the top of any part of a seat to
250 millimeters where the seat is at the extreme end or at
the extreme rear of the bleachers or grandstand. The
intervening space shall have one additional rail midway in
the opening: Except , that railings may be omitted when
stands are placed directly against a wall or fence giving
equivalent protection; stairs and ramps shall be provided
with guardrails. Handrails at the front of stands and
adjacent to an aisle shall be designed to resist a load of 75
kilograms per linear meter applied at the top rail. Other
handrails
shall
be
designed
to
resist
a load of 40
kilograms per linear meter.
(7) Foot Boards — Footboards shall be provided for all
rows of seats above the third row or beginning at such
point
where
the
seating
plank
is
more
than
600
millimeters above grade.
(8) Exits — (8.1) Distance to Exit — The line of travel to an
exit shall not be more than 45.00 meters. For stands with
seats without backseats this distance may be measured
by direct line from a seat to the exit from the stand.
(8.2) Aisle Used as Exit — An aisle may be considered as
only one exit unless it is continuous at both ends to a
legal building exit or to a safe dispersal area.
(8.3) Two Exits Required — A stand with the first seating
board not more than 500 millimeters above grade of floor
may be considered to have two exits when the bottom of
the stand is open at both ends. Every stand or section of a
stand within a building shall have at least two means of
egress when the stand accommodates more than 50
persons.
Every open air stand having seats without
backrest shall have at least two means of egress when the
stand accommodates more than 300 persons.
(8.4) Three Exits Required — Three exits shall be required
for stands within a building when there are more than
300 occupants within a stand and for open air stands
with seats without backrests where a stand or section of a
stand accommodates more than 1000 occupants.
(8.5) Four Exits Required — Four exits shall be required
when a stand or section of a stand accommodates more
than 1000 occupants: Except, that for an open air stand
with seats without backrests four exits need not be
provided unless there are accommodations for more than
3000 occupants.
(8.6) Width — The total width of exits in meters shall not
be less than the total occupant load served divided by 165:
Except, that for open air stands with seats without
backrests the total width of exits in meter shall not be less
than the total occupant load served divided by 500 when
existing by stairs, and divided by 650 when existing by
ramps or horizontally. When both horizontal and stair
exits are used, the total width of exits shall be determined
by using both figures as applicable. No exit shall be less
than 1.10 meters in width. Exits shall be located at a
reasonable distance apart. When only two exits are
provided, they shall be spaced not less than one-fifth of
the perimeter apart.
(9) Securing of Chairs — Chairs and benches used on
raised stands shall be secured to the platforms upon
which they are placed: Except, That when less than 25
chairs are used upon single raised platform the fastening
of seat to the platform may be omitted. When more than
500 loose chairs are used in connection with athletic
events, chairs shall be fastened together in groups of not
less than three, and shall be tied or staked to the ground.
(10) Safe Dispersal Area — Each safe dispersal area shall
have at least two exits. If more than 6000 persons are to
be accommodated within such an area, there shall be a
minimum of three exits, and for more than 9000 persons
there shall be a minimum of four exits. The aggregate
clear width of exits from a safe dispersal area shall be
determined on the bases of not less than one exit unit of
600
millimeters
for
each
500
persons
to
be
accommodated and not exit shall be less than 1.10 meters
in width, a reasonable distance apart that shall be spaced
not less than one-fifth of the perimeter of the area apart
from each other.
(o) Special Hazards — (1) Boiler Rooms — Except in Group
A
Occupancies,
every
boiler
room
and
every
room
containing an incinerator or liquefied petroleum gas or
liquid fuel-fired equipment shall be provided with at least
two means of egress, one of which may be a ladder. All
interior openings shall be protected as provided for in this
Code.
(2)
Cellulose
Nitrate
Handling
—
Film
laboratories,
projection rooms, and nitro-cellulose processing rooms
shall have not less than two exits.
SECTION 1208. Skylights . — (a) All skylights shall be
constructed with metal frames except those for Groups A
and J Occupancies. Frames of skylights shall be designed
to carry loads required for roofs. All skylights, the glass of
which is set at an angle of less than 45 degrees from the
horizontal, if located above the first storey, shall be set at
least 100 millimeters above the roof. Curbs on which the
skylights
rest
shall
be constructed of incombustible
materials except for Types 1 or 11 Construction.
(b) Spacing between supports in one direction for flat
wired glass in skylights shall not exceed 625 millimeters.
Corrugated wired glass may have supports 1.50 meters
apart in the direction of the corrugation. All glass in
skylights shall be wired glass: Except, that skylights over
vertical shafts extending through two or more storeys
shall be glazed with plain glass as specified in this Code:
Provided, that wire glass may be used in ventilation equal
to not less than one-eight the cross-sectional area of the
shaft but never less than 1.20 meters is provided at the
top of such shaft. Any glass not wire glass shall be
protected above and below with a screen constructed of
wire not smaller than 2.5 millimeters in diameter with a
mesh not larger than 25 millimeters. The screen shall be
substantially supported below the glass.
(c) Skylights installed for the use of photographers may
be constructed of metal frames and plate glass without
wire netting.
(d) Ordinary glass may be used in the roof and skylights
for
greenhouses,
Provided ,
That
height
of
the
greenhouses at the ridge does not exceed 6.00 meters
above the grade. The use of wood in the frames of
skylights will be permitted in greenhouses outside of
highly restrictive Fire Zones if the height of the skylight
does not exceed 6.00 meters above the grade, but in
other cases metal frames and metal sash bars shall be
used.
(e) Glass used for the transmission of light, if placed in
floors
or sidewalks, shall be supported by metal or
reinforced concrete frames, and such glass shall not be
less than 12.5 millimeters in thickness. Any such glass over
100 square centimeters in area shall have wire mesh
embedded in the same or shall be provided with a wire
screen underneath as specified for skylights in this Code.
All portions of the floor lights or sidewalk lights shall be of
the same strength as required for floor is surrounded by a
railing not less than 1.10 meters in height, in which case
the construction shall be calculated for not less than roof
loads.
SECTION 1209. Bays, Porches, and Balconies . — (a) Walls
and floors in bay and oriel windows shall conform to the
construction allowed for exterior walls and floors of the
type of construction of the building to which they are
attached. The roof covering of a bay or oriel window shall
conform to the requirements of the roofing of the main
roof. Exterior balconies attached to or supported by wall
required to be of masonry, shall have brackets or beams
constructed of incombustible materials. Railings shall be
provided for balconies, landings, or porches which are
more than 750 millimeters above grade.